AC Refrigerant Leaks are Dangerous

AC Refrigerant Leaks are Dangerous

 

Are you worried about a potential ac Freon leak? If your home air conditioning unit has stopped working or no longer cools when you turn it on, then there may be something wrong with your Freon.

MYTH : AC Freon must be charged every spring.

It’s a common myth that freon is slowly depleted through air conditioning use. Instead, a freon leak is most often caused by small puncture holes that allow the gas-liquid to escape. Other causes can include poor installation, factory defects in your unit, or formic acid or formaldehyde corrosion of the metal.

How can you spot air conditioning freon leaks?

Freon leaks can get a lot worse as time goes by. Just like an inflatable bed or beach ball, the hole often starts as a pinhole leak and becomes a bigger problem if not stopped. Bert’s Inc an expert air conditioning repair technician can detect these tiny holes by observing tiny bubbles in the evaporator coils. This location is where freon leaks are most often spotted.

Health and environmental effects of Freon.

Freon is certainly a health hazard. Freon is a toxic substance, and for this reason, freon leaks should be handled by an expert repair technician. Freon leaks deplete the ozone layer and is unsafe for the environment. The biggest concern with freon leaks is assuring that no freon enters the airflow inside the interior of your home. If you start to experience a foul-smelling odor escaping your HVAC system during operation, then you could have a freon leak. Call Bert’s Inc Immediately!

Common causes and solutions for A/C freon leaks.

Freon leaks are not as common as you may think. A brand new air conditioning unit has the potential to leak freon if not installed properly. In the beginning, a good air conditioning repair technician rules out freon leaks by testing the system’s soldering.

The second most common thing that can lead to freon leaks is damage. Any sort of damage your air conditioning unit can cause separate components to fail. Be careful with your lawn mowers and trimers around the outdoor ac unit.

The most common cause of ac freon leak is likely erosion from either formic acid or formaldehyde corrosion. Small holes are formed when the acid eats away at the metal and the unit eventually releases freon. This can be repaired by replacing the separate components such as the coils or installing a new air conditioning unit depending on the damage.

Finally, the last major cause of freon leaks are factory defects. There’s no way for you to know your brand new air conditioning unit is defective when it comes to holding freon, unless you consult an expert air conditioning repair technician. Not to mention, most air conditioning manufacturing companies void the warranty if repairs are made by someone other than a trained technician, so get in touch with an air conditioning repair company if you suspect your brand new ac is leaking freon. It’s not uncommon to find freon leaks 5 to 10 years after the initial air conditioning installation!

Do you need someone to find and fix an ac freon leak? Get in touch with an expert air conditioning repair technician at Bert’s Inc. We offer emergency 24/7 ac repair.

Does a Freon leak mean I need a new A/C Unit?